Findings

Finding cards

The defects we see most often on site: what was seen, why it matters, what to do.⁠⁠‍​‌​‌‌‌⁠‍‍‌​​‌​​⁠⁠⁠‌‌

The findings we meet most often on surveys. Each card gives what was seen, why it matters and what to do in three sentences, with the instrument used to find it underneath.⁠⁠‍​‌​‌‌‌⁠‍‍‌​​‌​​⁠⁠⁠‌‌

Star cracks in gelcoat
Star cracks in gelcoat

Hull

Star cracks in gelcoat

What was seen
Hairline cracks radiating from a centre around cleat and winch bases.
Why it matters
They mark a point load or an impact; water can get through to the laminate and core beneath.
What to do
The area is checked for moisture; if dry, a gelcoat repair, if wet, the structure underneath first.

Found with: 30× loupe

Osmosis blisters below the waterline
Osmosis blisters below the waterline

Hull

Osmosis blisters below the waterline

What was seen
Blisters from pinhead to lentil size under the waterline; some weep an acidic fluid when opened.
Why it matters
They show the laminate is taking on water; repair cost and time grow quickly as it progresses.
What to do
A moisture map is taken; depending on extent, drying and an epoxy barrier, or monitoring.

Found with: Tramex Skipper Plus moisture meter

Opening at the keel-hull joint
Opening at the keel-hull joint

Hull

Opening at the keel-hull joint

What was seen
A clear crack and paint separation along the keel joint, at the leading edge.
Why it matters
It can point to a grounding or loose keel bolts; the internal structure may be damaged.
What to do
Keel bolts and the internal floor structure are inspected; if needed, the keel is dropped and rebedded.

Found with: Phenolic sounding hammer

Wet core in the transom
Wet core in the transom

Hull

Wet core in the transom

What was seen
High moisture readings and a dull sound in the transom around the ladder and exhaust outlet.
Why it matters
A wet core rots or separates, and the transom carries load.
What to do
The wet area is mapped and the entry point sealed; if extensive, the core is replaced.

Found with: Tramex Skipper Plus moisture meter

Wet core around deck fittings
Wet core around deck fittings

Deck

Wet core around deck fittings

What was seen
Moisture readings rise around winch and track bases; the deck flexes underfoot.
Why it matters
Water entering through bolt holes soaks the sandwich core, and the deck loses stiffness over time.
What to do
Fittings are removed and rebedded; wet core is cut out and filled or replaced.

Found with: Tramex Skipper Plus moisture meter

Leaks at portlights and hatches
Leaks at portlights and hatches

Deck

Leaks at portlights and hatches

What was seen
Water staining and lifting of the interior lining below the portlights.
Why it matters
Leaks damage linings, timber and sometimes wiring; the source is often higher than it looks.
What to do
Seals and bedding are renewed; cracked acrylic is replaced.

Found with: Borescope camera

Teak deck seams and plugs failing
Teak deck seams and plugs failing

Deck

Teak deck seams and plugs failing

What was seen
Teak worn, seams lifting, some plugs gone and screw heads showing.
Why it matters
Water gets through screw holes to the deck and core beneath.
What to do
Remaining teak thickness is measured; if enough, re-caulking and new plugs, if not, replacement is planned.

Found with: 30× loupe

Corroded exhaust elbow
Corroded exhaust elbow

Engine

Corroded exhaust elbow

What was seen
Salt crystals and rust on the outside of the mixing elbow; high elbow temperature on sea trial.
Why it matters
The elbow narrows or perforates inside; water can reach the engine or exhaust can leak into the engine room.
What to do
The elbow is removed and checked inside; usually it is replaced.

Found with: Infrared thermometer

Collapsed engine mounts
Collapsed engine mounts

Engine

Collapsed engine mounts

What was seen
Mount rubbers oil-soaked and cracked; the engine sits low on one side.
Why it matters
Shaft alignment is lost; the vibration wears the gearbox, gland and bearings.
What to do
Mounts are replaced and the shaft realigned.

Found with: Vibration meter

Salt build-up and leaks in the cooling circuit
Salt build-up and leaks in the cooling circuit

Engine

Salt build-up and leaks in the cooling circuit

What was seen
White salt deposits at raw-water pump and heat exchanger joints; drips beneath the pump.
Why it matters
As cooling weakens the engine runs hot; the leak also damages the pump shaft and belts.
What to do
Pump seal and impeller are renewed, the heat exchanger cleaned and joints re-made.

Found with: Thermal camera

Hardened, cracked fuel hoses
Hardened, cracked fuel hoses

Engine

Hardened, cracked fuel hoses

What was seen
Fuel hoses hard with fine cracks on the outside; manufacture date unreadable.
Why it matters
A fuel leak is a fire risk and lets air into the engine.
What to do
Hoses are replaced with marine fuel hose and proper clamps.

Found with: 30× loupe

Stern gland taking too much water
Stern gland taking too much water

Shaft, propeller, rudder

Stern gland taking too much water

What was seen
A continuous drip from the stuffing box under way, with rust and salt around it.
Why it matters
Water enters the bilge continuously; the packing may be spent or badly adjusted, and the shaft can wear.
What to do
The packing is adjusted or renewed; if the shaft is worn, shaft and tube are assessed.

Found with: Borescope camera

Play in the rudder bearings
Play in the rudder bearings

Shaft, propeller, rudder

Play in the rudder bearings

What was seen
The rudder blade moves sideways when pushed by hand; play is felt in the bearing.
Why it matters
As play grows the bearings and stock wear, and control weakens in heavy weather.
What to do
Bearing clearance is measured; above the limit, bearings are renewed.

Found with: Laser distance meter

Propeller cavitation and blade tip damage
Propeller cavitation and blade tip damage

Shaft, propeller, rudder

Propeller cavitation and blade tip damage

What was seen
Nicks and bends at the blade tips, spongy erosion on the blade face.
Why it matters
Efficiency drops and vibration rises, passing into the shaft and gearbox.
What to do
The propeller goes to a specialist for repair and balancing; if erosion is advanced, it is replaced.

Found with: 30× loupe

Overheating electrical connection
Overheating electrical connection

Electrical

Overheating electrical connection

What was seen
On the thermal camera, one pole of the main battery switch is markedly hotter.
Why it matters
A loose or corroded connection heats up; it is a common starting point for fires on board.
What to do
The connection is taken apart and cleaned, the terminal renewed and torqued correctly.

Found with: Thermal camera

Unfused circuit added later
Unfused circuit added later

Electrical

Unfused circuit added later

What was seen
A circuit added for extra equipment in household cable with terminal blocks, and no fuse.
Why it matters
Nothing protects the circuit in a short; household cable fails quickly with vibration and damp.
What to do
The circuit is rerun in marine cable, fused and labelled.

Found with: True RMS clamp meter

Leakage current on shore power
Leakage current on shore power

Electrical

Leakage current on shore power

What was seen
A steady current measured on the earth conductor with shore power connected.
Why it matters
Leakage is a shock hazard and drives fast corrosion of underwater metals.
What to do
The source is traced circuit by circuit; an isolation transformer or galvanic isolator is considered.

Found with: True RMS clamp meter

Spent anodes and low protection
Spent anodes and low protection

Corrosion

Spent anodes and low protection

What was seen
Saildrive and shaft anodes largely wasted; protection measured with the reference electrode is inadequate.
Why it matters
Once anodes are gone, corrosion moves to expensive parts: the saildrive leg, propeller and shaft.
What to do
Anodes are renewed, bonding checked and the reading repeated after relaunch.

Found with: Zinc reference electrode

Hairline crack in a rigging terminal
Hairline crack in a rigging terminal

Rig

Hairline crack in a rigging terminal

What was seen
A lengthwise hairline crack at the neck of a lower shroud terminal, seen under the loupe.
Why it matters
A terminal can fail without warning, and a failed shroud can bring the mast down.
What to do
The terminal is replaced, and if needed all wire of the same age.

Found with: 30× loupe

Out-of-date gas hose, blocked locker drain
Out-of-date gas hose, blocked locker drain

Gas system

Out-of-date gas hose, blocked locker drain

What was seen
The gas hose is well past its manufacture date and the gas locker drain is blocked.
Why it matters
LPG is heavier than air; if the drain fails, leaked gas collects in the bilge and becomes an explosion risk.
What to do
The hose is replaced, the drain cleared and joints checked with a leak-detection solution; a pressure test is done by a qualified gas fitter.

Found with: 30× loupe

Continue with this topic

Request a Survey Online

Fill in the form and we will come back with an itemised written quotation.

📋 Survey Request Form

What Is in the Survey Report?

See the report section by section: how findings are structured and what the measurement tables contain.

📄 See the Report Contents
📞 Call 💬 WhatsApp